| Application Type | Industrial |
| Display Type | LCD |
| Sensor Type | Fuel Cell |
| Brand | Amrutha |
| Warning Signal | Beep |
| Model | Fuel-Cells Sensor Models |
| Types Of Breath Alcohol Analyzer | Fuel-Cells Sensor Models |
| Display | LCD Display |
Product Description: This Breath Analyzer with Inbuilt Printer A50 is mainly known for rough and tough use.
Features:
Specification:
- Measurement Mode: Active Mode and Passive Mode
- Sensor type: Fuel cell Sensor
- Display: 2.8 inch full graphic TFT display
- Mouth Pieces: Yes
- Measurement Range: (0-550) mg/100ml BAC
- Memory: 20,000
- Zeroing Time: < 5 sec
- Operating Temp: -5C +50ºC
- Printer: In-Built.
- Real Time clock: Yes.
- Measurement time: < 10 sec
- Battery: 7.4V, 1300mAH rechargeable Li-ion battery
- Device Interface: USB data can be transmitted to Printer or PC
- Software Moment: Data transmit and storage option
- Dimension: 180mm x 70mm x 30mm
- Weight: 250gm
AMRUTHA
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
| Application Type | Industrial |
| Display Type | LCD |
| Sensor Type | Fuel Cell |
| Instrument Name | Breath Analyser |
| Model Name/Number | A50 |
| Display | LCD Display |
| Country of Origin | Made in India |
| PRODUCT BRAND | AMRUTHA |
Professional Alcohol Breath Analyser Model – A20
Touch Screen with Inbuilt Thermal Printer
20,000 Memories with GPS.
Data collection report using PC Software utility
|
Measurement Mode |
Active Mode and Passive Mode |
|
|
Sensor type |
Fast Fuel Sensor |
|
|
Display |
2.4 inch color TFT display |
|
|
Mouth Pieces |
Yes |
|
|
Units |
ºC, mg/L, mg/100ml BAC |
|
|
Measurement Range |
(0-550) mg/100ml BAC |
|
|
Accuracy |
Range (0-88) mg/100ml |
± 4.4 mg/100ml |
|
Range(88-220)mg/100ml |
± 5% absolute |
|
|
Range > 220mg/100m |
± 10% absolute |
|
|
Measurement Range |
(0-2.5) mg/L BrAC |
|
|
Accuracy |
Range ( 0.00-0.40) mg/L |
± 0.020 mg/L |
|
Range ( 0.40-1.00) mg/L |
± 5% absolute |
|
|
Range > 1.00 mg/L |
Range > 1.00 mg/L |
|
|
Memory |
20,000 |
|
|
Pre Heating Time |
About 5 sec |
|
|
Operating Temp |
-5ºC – +50ºC |
|
|
Condition pressure |
600-1400 hPa |
|
|
Condition Humidity |
20-98% r.h. |
|
|
Measurement time |
More than 1000 times testing |
|
|
Power Save Mode |
Automatic switch off after 2.5 minutes without use |
|
|
Battery |
7.4V, 1300mAH rechargeable Li-ion battery |
|
|
Device Interface |
USB data can be transmitted to Printer or PC |
|
|
Software Management |
PC Data Manager, data transmit and storage option |
|
|
Dimension |
170mm x 70mm x 30mm |
|
|
Weight |
125gm including battery |
|
|
Calibration |
Every 6 months or defined by local government |
|
Additional Information:
View Complete details
Product Brochure
| Application Type | Industrial |
| Display Type | Digital |
| Sensor Type | Fuel Cell |
| Grade | Manual |
| Brand | AMRUTHA |
| Warning Signal | Beep |
| Model Name/Number | Fuel-Cells Sensor Models |
| Usage/Application | Workplace |
|
Details |
Technical Data |
||
|
Principle of measurement |
Electrochemical Sensor, alcohol-specific |
||
|
Measurement Range |
0~ 80mg/100ml BAC |
||
|
Test Mode |
For quick testing, automatic sampling |
||
|
Way of Breath Sample Extraction |
Motor continuous air extraction, speed no less than 0.8L |
||
|
Temperature Range-operation |
-5°C~45°C |
||
|
Temperature Range-storage |
-30°C~70°C |
||
|
Measuring Time |
Adjustable( Minimum time: 1 second) |
||
|
Working Pressure |
600~1400hPa |
||
|
Working Temperature |
20~98%r.h. |
||
|
Screen |
OLED Digital Screen |
||
|
Battery |
1 rechargeable battery, 3.7V/3000mAh |
||
|
Continuous Working Time |
More than 8 hours |
||
|
Flashing Light |
2 lights of 3W |
||
|
Vibration Alarm |
When the concentration exceed the set point value, device will give Vibration Alarm |
||
|
Dimensions |
L(330)mm X Outer Diameter(45)mm |
||
|
Weight |
Approx. 254g |
||
|
Test item |
Blowing distance 4-5cm |
||
|
Test concentration(mg/100ml) |
|||
|
20 |
40 |
150 |
|
|
Analyzing time |
<5s |
||
|
Clearing time |
<10s |
||
|
Measuring range |
15~35 |
35~65 |
>80 |
View Complete details
Product Brochure
| Application Type | Industrial |
| Display Type | LCD |
| Sensor Type | Fuel Cell |
| Brand | AMRUTHA |
| Warning Signal | Beep |
| Display | LCD Display |
| Type Of Mouthpiece | Replaceable |
| Power Supply | 1pc 9V battery |
The AT188 personal breathalyzer has a digital display, more compact, easy to use and provides accurate readings. Applications: This device is best used to help your friends and colleagues make responsible decisions after consuming alcohol.
Features: Advanced flat surfaced sensor Portable and small size design No touch healthy design Low voltage indication Use AAA battery Technical data Sensor
Type: Advanced flat surfaced sensor
Test range:
0.00-0.20%BAC;0.00-1.00mg/L
; 0.00-2.00‰BAC;0.00-2.00g/L;
Warmup up time: Around 35s
Working Temp: 0 -50
Working Humidity: ≤93% RH No dews
Display Screen: LCD Display
Power: AAA battery
Dimension: 123m*44m*19mm
Weight: About 50g(without battery)
Accuracy: ±0.02%BAC at 0.05%BAC
View Complete details
Product Brochure
| Application Type | Industrial |
| Display Type | Digital |
| Sensor Type | Fuel Cell |
| Brand | AMRUTHA |
| Instrument Name | Breath Analyser |
| Type Of Breath Alcohol Analyzer | Fuel Cells Sensor Models |
| Usage/Application | Clinical |
| Parameters | Blood Alcohol Content |
Key Specifications/Special Features
FDA:
o ???Built-in printer (optional)
o Built-in GPS
o 50,000 tests records stored in memory
o 4.3" color touch screen
o 3G/Wi-Fi
o Press-button mouthpiece release
o Photo capture
o Provide evidential records by auto capturing while subject blowing
o USB PC connection
Sensor | Fuel cell |
Working Temperature | -10 to 50°C |
Storage Temperature | -30 to 70°C |
Wireless Communication | 3G, Wi-Fi |
Size | 212 x 80 x 36mm |
Weight | 423g with batteries |
Battery | 7.4V 1800mAh NI-MH rechargeable battery |
Battery Life | 700 tests (over 250 tests with printouts) |
Memory | 50,000 tests records including all information |
Display | 4,3" TFT color touch screen |
Optional Power | Supply 12 volt car adapter or AC 6 volt adapter |
Sampling System | Automatically or manually take a deep lung sample |
Camera | 5 Megapixel 120° wide angle lens |
Units of Measure | BrAC: mg/L, or any other units |
Detection Range | 0.00% BAC to 0.40% BAC |
Accuracy | 0-0.10% BAC: +/-5% |
GPS | -5M to +5M |
Printer | Thermal printer |
Connection | USB |
PC Download | Yes |
View Complete details
Product Brochure
| Application Type | Industrial |
| Display Type | LCD |
| Sensor Type | Fuel Cell |
| Brand | Amrutha |
| Model | Fuel-Cells Sensor Models |
| Instrument Name | Breath Analyser |
| Model Number/Name | Jupiter X |
| Automation | Manual |
| Weight | 423 gm with batteries |
| Battery | 7.4 V 1800 mAh NI-MH rechargeable battery |
| Size | 212 x 80 x 36 mm |
| Wireless Communication | 3G, Wi-Fi |
| Storage Temperature | -30 to 70 Deg C |
| Working Temperature | -10 to 50 Deg C |
| Sensor | Fuel Cell |
Special Features:
FDA:|
Battery Life |
700 tests (over 250 tests with printouts) |
|
Memory |
50,000 tests records including all information |
|
Display |
4,3" TFT color touch screen |
|
Optional Power |
Supply 12 volt car adapter or AC 6 volt adapter |
|
Sampling System |
Automatically or manually take a deep lung sample |
|
Camera |
3 Megapixel 120° wide angle lens |
|
Units of Measure |
BrAC: mg/L, or any other units |
|
Detection Range |
0.00% BAC to 0.40% BAC |
|
Accuracy |
0-0.10% BAC: +/-5% |
|
GPS |
-5M to +5M |
|
Printer |
Thermal printer |
|
Connection |
USB |
|
PC Download |
Yes |
View Complete details
Product Brochure
| Application Type | Industrial |
| Display Type | Digital |
| Sensor Type | Fuel Cell |
| Packaging Type | Box |
| Usage/Application | Industrial |
| Country of Origin | Made in India |
| PRODUCT BRAND | AMRUTHA |
| PRODUCT MODEL | WORKPLACE 5 |
|
Test Mode: |
Rapid Scan Mode |
|
Sensor Type: |
The fuel cell sensor is insensitive to gases such as acetone and carbon monoxide, the influence is negligible. |
|
Input method: |
Touch screen + Fingerprint module |
|
Blowing Time: |
^ 2 seconds |
|
Operating temperature range: |
-10°C to +50°C |
View Complete details
Product Brochure
| Application Type | Industrial |
| Display Type | LCD |
| Sensor Type | Fuel Cell |
| Grade | Manual |
| Mouthpiece Type | Replaceable |
| Portability | Portable |
| Brand | Amrutha |
| Usage/Application | Industrial |
| Country of Origin | Made in India |
| PRODUCT BRAND | AMRUTHA |
| PRODUCT MODEL | AMRUTHA A65 |
. SENSOR: FUEL CELL SENSOR
2. MEASUREMENT MODE: PASSIVE, ACTIVE
3. MEASUREMENT RANGE: 0 TO 550 MG/100 ML
4. ACCURACY: + 5% OF MEASURE VALUE
5. OPERATION TEMPERATURE: -5 TO +55 DEGREE C
6. STORAGE TEMPERATURE: -20 TO 60 DEGREE C
7. PRESSURE: 600 TO 1400 hpa
8. HUMIDITY: 20 TO 98 % R.H
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
| Application Type | Industrial |
| Display Type | Digital |
| Sensor Type | Fuel Cell |
| Packaging Type | Box |
| Grade | Manual |
| Material | Stainless Steel |
| Model | Amrutha 2010P |
| PRODUCT BRAND | AMRUTHA |
View Complete details
Product Brochure
| Application Type | Industrial |
| Display Type | Digital |
| Sensor Type | Fuel Cell |
| Grade | Manual |
| Warning Signal | Light |
| Display | LED Display |
| Country of Origin | Made in India |
| PRODUCT BRAND | AMRUTHA |
View Complete details
Product Brochure
| Application Type | Industrial |
| Display Type | Digital |
| Sensor Type | Fuel Cell |
| Grade | Manual |
| Material | Stainless Steel |
| Usage/Application | Industrial |
| Country of Origin | Made in India |
| PRODUCT BRAND | AMRUTHA |
Range: Low & 0.15 ~ 2.20 ‰ BAC, HI
Accuracy: ±0.18 ‰BAC (0.018ºC)
at the Calibrated point (alert level).
Power Input: 3.7V Rechargeable Li ion battery (included)
Display: Digital display with 0.01‰BAC resolution
Memories: 10 records
Unit: mg/l, ºC, mg/100ml and ‰BAC
Auto power off: 2 minutes
Breath sampling: about 5 seconds continuous breath sample
Cycle time: about 20 seconds
AMRUTHA
View Complete details
Product Brochure
| Detection Range | 9 INCH |
| Colour | Black |
| Battery Type | Rechargeable |
| PRODUCT MODEL | GARRETT SUPER SCANNER |
| PRODUCT BRAND | AMRUTHA GARRETT |
|
Brand |
Garrett |
|
Alarm Mode |
Sound |
|
Warranty |
1Year against manufacturing defects only. |
|
Battery Requirements |
One 9V (included). Provides up to 80 hours of normal operation. |
|
Total Weight |
18.6 oz (527 g) |
|
Length |
19" (48.3 cm) |
|
Thickness |
1.25" (3.2 cm) |
|
Width |
3.25" (8.3 cm) |
|
Operating Temperatures |
-35 Degree F (-37 Degree C) to 158 Degree F (70 Degree C) |
|
Audio Frequency |
2 kHz Warble |
|
Tuning |
Automatic |
|
Controls |
Power switch (Audible / Off / Silent) Interference Elimination Switch |
View Complete details
Product Brochure
| Application Type | Industrial |
| Display Type | Digital |
| Sensor Type | Fuel Cell |
| Brand | AMRUTHA |
| Instrument Name | Breath Analyser |
| Model Number/Name | JUPITER X |
| Usage/Application | INDUSTRIAL / POLICE / TRANSPORT |
| Display | Digital |
AT-BPG-CAMERA Key Specifications/Special Features
Sensor | Fuel cell |
Working Temperature | -10 to 50°C |
Storage Temperature | -30 to 70°C |
Wireless Communication | 3G, Wi-Fi |
Size | 212 x 80 x 36mm |
Weight | 423g with batteries |
Battery | 7.4V 1800mAh NI-MH rechargeable battery |
Battery Life | 700 tests (over 250 tests with printouts) |
Memory | 50,000 tests records including all information |
Display | 4,3" TFT color touch screen |
Optional Power | Supply 12 volt car adapter or AC 6 volt adapter |
Sampling System | Automatically or manually take a deep lung sample |
Camera | 3 Megapixel 120° wide angle lens |
Units of Measure | BrAC: mg/L, or any other units |
Detection Range | 0.00% BAC to 0.40% BAC |
Accuracy | 0-0.10% BAC: +/-5% |
GPS | -5M to +5M |
Printer | Thermal printer |
Connection | USB |
PC Download | Yes |
View Complete details
Product Brochure
| Application Type | Industrial |
| Display Type | Digital |
| Sensor Type | Fuel Cell |
| Mouthpiece Type | Replaceable |
| Portability | Portable |
| Accuracy | 0.01 % |
| Substance Tested | Alcohol |
| Sample Type | Breath |
|
Test Mode: |
Rapid Scan Mode |
|
Sensor Type: |
The fuel cell sensor is insensitive to gases such as acetone and carbon monoxide, the influence is negligible. |
|
Input method: |
Touch screen + Fingerprint module |
|
Blowing Time: |
^ 2 seconds |
View Complete details