Product Brochure
Instrument Name | Breath Analyser |
Application | Law Enforcement Agencies |
Brand | Amrutha |
Parameters | Blood Alcohol Content |
Automation | Manual |
Measurement Range | (0-550) mg/100ml BAC |
Display | 2.8 inch full graphic TFT display |
Model | Digital |
Mouth Pieces | Yes |
Memory | 20000 |
Zeroing Time | < 5 sec |
Operating Temperature | -5C +50 Degree Celsius |
Printer | In-Built |
Real Time Clock | Yes |
Measurement Time | < 10 sec |
Battery | 7.4V, 1300mAH rechargeable Li-ion battery |
Dimension | 180 x 70 x 30 mm |
Weight | 250 gm |
View Complete details
Instrument Name | Breath Analyser |
Brand | Amrutha |
Display | 2.2 inch LCD display, LCD Display |
Operation Mode | Manual |
Power Source | Battery |
Storage Environment Temperature | -20 Degree Celsius to +75 Degree Celsius |
Operating Temperature | 5 to +45 Degree Celsius for optimum operation |
Memories | 200 Records |
Printer Interface | RS232 cable |
Indicator | Instructing LED for indication |
Dimension | 103 x 55 x 15 mm |
Measurement Accuracy | +/-0.03 mg/L at alert point |
View Complete details
Instrument Name | Breath Analyser |
Brand | Amrutha |
Parameters | Blood Alcohol Content |
Display | Blue backlight 3-digit LCD screen |
Operation Mode | Manual |
Sensor | High-precision semiconductor alcohol sensor |
Response Time | Less Than 5s |
Warm-up Time | Less Than 20s |
Operating Current | Less Than or Equal 120mA |
Operating Temperature | 10 Degree Celsius ~ 50 Degree Celsius |
Operating Voltage | 3 x AAA alkaline battery (Not included) |
Weights | 68.5g (excluding batteries) |
Dimension | 112 x 61 x 29 mm |
Detection Range | 0.000-0.199% BAC |
0.000-1.990 ‰BAC | |
0.000-0.990mg/L (BrAC) | |
Alarm point | 0.050% BAC |
0.500 ‰BAC | |
0.250mg/L (BrAC) | |
Accuracy | ±0.010% BAC |
±0.100‰ BAC | |
±0.250mg/L |
View Complete details
Instrument Name | Breath Analyser |
Brand | Amrutha |
User Input | Air Blow |
Display | 4.3 inch TFT color touch screen |
Memory | 50,000 tests records including all information |
Weight | 423g with batteries |
Sensor | Fuel cell |
Working Temperature | -10 to 50 Degree Celsius |
Storage Temperature | -30 to 70 Degree Celsius |
Wireless Communication | 3G, Wi-Fi |
Size | 212 x 80 x 36mm |
Battery Capacity | 1800 mAh |
Battery Voltage | 7.4 V |
Battery Life | 700 tests (over 250 tests with printouts) |
Optional Power | Supply 12 volt car adapter or AC 6 volt adapter |
Sampling System | Automatically or manually take a deep lung sample |
Camera | 3 Megapixel 120° wide angle lens |
Units of Measure | BrAC: mg/L, or any other units |
BrAC: grm%, mg/ml, mg/100ml, or any other units | |
Detection Range | 0.00% BAC to 0.40% BAC |
Accuracy | 0-0.10% BAC: +/-5% |
0.10-0.15ºC: +/-8% | |
>0.15: +/-10% | |
GPS | -5M to +5M |
Printer | Thermal printer |
Connection | USB |
PC Download | Yes |
View Complete details
Instrument Name | Breath Analyser |
Usage/Application | Laboratory |
Parameters | Blood Alcohol Content |
Brand | Amrutha |
Type Of Breath Alcohol Analyzer | Fuel Cells Sensor Models |
Display | LCD Display |
Operation Mode | Manual |
Storage Environment Temperature | -20 Degree Celsius to +75 Degree Celsius |
Operating Temperature | 5 to +45 Degree Celsius |
Memories | 200 Records |
Dimension | 103 x 55 x 15 mm |
Measurement Accuracy | +/-0.03 mg/L |
Features:
View Complete details
Instrument Name | Breath Analyser |
Usage/Application | Law Enforcement Agencies |
Brand | Amrutha |
Parameters | Blood Alcohol Content |
Type Of Breath Alcohol Analyzer | Fuel Cells Sensor Models |
Operation Mode | Manual |
Dimensions | 103 x 55 x 15 mm |
Memory | 200 Slots |
Detection Range | +/-0.03 mg/L |
Display Size | 2.2 inch Display Keyboard |
Model No | PT-200P |
Operating Temperature | 5 + 40 Degree Celsius |
Power Source | Battery |
1. Display: | 2.2” LCD display |
2. Keyboard | 5 keys operation: ,“Up”, “Down”, “Left”, “Right”, “OK” |
3. Power Supply | Interchangeable rechargeable battery; |
4. Heat warm up:: | Chamber & Sensor warm up automatically |
5. Auto flow monitoring. | Flow detect automatically (Patented) |
6. Compact sampling system: | Low power consumption (Patented) |
7. Passive test: | Quick test within 1 sec. |
8. Storage environment | -20 Degree C to +75 Degree C. |
9. Operating Temperature : | From 5??? to +45 ???, for optimum operation |
10. Operating Temperature : | From 5??? to +45 ???, for optimum operation |
11. Memories | 200 Records |
12. Printer interface (OPTION) | By RS232 cable (Printer not included) |
13. Indicator | Instructing LED for indication |
14. Dimension: | About 103 * 55 * 16 mm3 |
15. Measurement Accuracy: | +/–0.03 mg/L at alert point Drift: typically, < 1.0 % of the measurement value/month |
16. CERTIFICATED | GB/T 21254-2007; Ukraine Mark II |
16. Standard gift box packing: | Including White box; 2 pcs blow tubes , USB charger cable; |
View Complete details
Instrument Name | Breath Analyser |
Model Number/Name | Jupiter X |
Brand | Amrutha |
Automation | Manual |
Display | 4,3" TFT color touch screen |
Memory | 50,000 tests records including all information |
Weight | 423g with batteries |
Sensor | Fuel cell |
Working Temperature | -10 to 50 Degree Celsius |
Storage Temperature | -30 to 70 Degree Celsius |
Wireless Communication | 3G, Wi-Fi |
Size | 212 x 80 x 36 mm |
Battery Capacity | 1800 mAh |
Battery Voltage | 7.4 V |
Battery Life | 700 tests (over 250 tests with printouts) |
Optional Power | Supply 12 volt car adapter or AC 6 volt adapter |
Sampling System | Automatically or manually take a deep lung sample |
Camera | 3 Megapixel 120° wide angle lens |
Units of Measure | BrAC: mg/L, or any other units |
BrAC: grm%, mg/ml, mg/100ml, or any other units | |
Detection Range | 0.00% BAC to 0.40% BAC |
Accuracy | 0-0.10% BAC: +/-5% |
0.10-0.15ºC: +/-8% | |
>0.15: +/-10% | |
GPS | -5M to +5M |
Printer | Thermal printer |
Connection | USB |
PC Download | Yes |
View Complete details
Usage/Application | Law Enforcement Agencies |
Brand | AMRUTHA |
Warning Signal | Beep |
Measurement Range | 0.001 - 0.019 |
Accuracy | 5% |
Display | LCD Display |
Type Of Mouthpiece | Replaceable |
Model Name/Number | Fuel-Cells Sensor Models |
Analyzing Time | 3 s |
Product Description: This Breath Analyzer with Inbuilt Printer A50 is mainly known for rough and tough use.
Specification:
- Measurement Mode: Active Mode and Passive Mode
- Sensor type: Fuel cell Sensor
- Display: 2.8-inch full graphic TFT display
- Mouth Pieces: Yes
- Measurement Range: (0-550) mg/100ml BAC
- Memory: 20,000
- Zeroing Time: < 5 sec
- Operating Temp: -5C +50ºC
- Printer: In-Built.
- Real Time clock: Yes.
- Measurement time: < 10 sec
- Battery: 7.4V, 1300mAH rechargeable Li-ion battery
- Device Interface: USB data can be transmitted to Printer or PC
- Software Moment: Data transmit and storage option
- Dimension: 180mm x 70mm x 30mm
- Weight: 250gm
- Display: 2.8-inch full graphic TFT display
View Complete details
Usage/Application | Law Enforcement Agencies |
Brand | AMRUTHA |
Warning Signal | Beep |
Measurement Range | 0.00 to 4.00 mg/liter BrAC |
Accuracy | 5% |
Features | FUEL CELL |
Display | LCD Display |
Type Of Mouthpiece | Replaceable |
Model Name/Number | Fuel-Cells Sensor Models |
Analyzing Time | 3 s |
Technical Specifications
Pre-heating time: about 5 seconds
Zero time:
The previous measure is 0 mg/100ml about 3 seconds
The previous measure is 100 mg/100ml below about 5 seconds
The previous measure is >100 mg/100ml about 7 seconds
Sensor type Electrochemical fuel cell
Printer Built-in Printer
Items Car Number Police Number License Number
Cross sensitivity No
Mouth pieces Disposable, single way
Units ‰BAC, mg/L BrAC, mg/100ml BAC Add upon customer's requests
Use interface: Menu operation
Buttons: Touch Screen, 2 buttons
Power save mode: Automatic switch off after 2.5 minutes without use
Use Interface: 4.0-inch touch screen and color TFT display
Memory: Up to 100,000 measured values with date and time
Software management: PC data manager, data transmit and storage option
Calibration: Every 6 months or determined by local government
Camera:
Pixel: Five million pixels, Automatic focusing
Infrared: Yes
Fingerprint: Yes
GPS Yes
View Complete details
Product Brochure
Instrument Name | Breath Analyser |
Parameters | Blood Alcohol Content |
User Input | Touch |
Brand | Amrutha |
Type Of Breath Alcohol Analyzer | Fuel Cells Sensor Models |
Operation Mode | Manual |
Weight | 300 gm |
Power Source | Battery |
Operating Temperature | -20 Degree Celsius to + 70 Degree Celsius (0 Degree Celsius to +40 Degree Celsius |
Dimension | 188 x 78 x 33 mm |
Battery Capacity | 2300mAh |
View Complete details
Product Brochure
Instrument Name | Breath Analyser |
Usage/Application | Law Enforcement Agencies |
Brand | Amrutha |
Parameters | Blood Alcohol Content |
User Input | Touch |
Type Of Breath Alcohol Analyzer | Fuel Cells Sensor Models |
Operation Mode | Manual |
Calibration | Every 6 months |
Dimensions | 190 x 82 x 36 mm (L x W x H) |
Weight | 470g |
Resolution | 0.0001 mg/L |
Blowing Time | 3 sec |
Warm-up Time | 6 seconds after switching on |
Display Size | 2.8 inch |
Communication Method for Printer | Bluetooth |
Features:
View Complete details
Instrument Name | Breath Analyser |
User Input | Touch |
Accuracy | +/- 0.0151/4A at 0.05 degree Celsius |
Type Of Breath Alcohol Analyzer | Fuel Cells Sensor Models |
Features | LCD Display |
Operation Mode | Manual |
Measuring Range | 0.00-2.0(1.00mg/L) |
Size | 115 x 60 x 23 mm |
Blowing Time | 4 to 5 seconds continuously |
Packaging Type | Box |
Body Material | ABS Plastic |
Power Source | Battery |
Features:
View Complete details
Instrument Name | Breath Analyser |
Model Number/Name | FIT 333P |
Brand | Amrutha |
Display | Digital |
Analyzing time | 3 s |
Temperature Range | 20 Degree Celsius to +70 Degree Celsius, (-20 Degree Celsius to +40 Degree Celsius |
Display Size | 3.2 inch |
Display Range | 0~0.4% BAC or 0~4.0%o BAC or 0~2.0mg/l |
Storage Environment Temperature | -40 Degree Celsius to +85 Degree Celsius |
Power Source | Electric |
Battery Capacity | 2500 mAh |
View Complete details
Instrument Name | Breath Analyser |
Brand | Amrutha |
Types Of Breath Alcohol Analyzer | Fuel-Cells Sensor Models |
Display | Digital |
Analyzing time | 3 s |
Temperature Range | -20 Degree Celsius to +70 Degree Celsius (-20 Degree Celsius to +40 Degree Celsius |
Power Source | Battery |
Battery Capacity | 2500 mAh |
Display Range | 0~0.4% BAC or 0~4.0%o BAC or 0~2.0mg/l |
Storage Environment Temperature | -40 Degree Celsius to +85 Degree Celsius |
Body Material | ABS Plastic |
Features:
View Complete details
Minimum Order Quantity: 1 Piece
Instrument Name | Breath Analyser |
Usage/Application | Hospital |
Parameters | Blood Alcohol Content |
User Input | Touch |
Measurement Range | 0-2398ug/L |
Accuracy | <24ug/L 384ug/L |
Type Of Breath Alcohol Analyzer | Fuel Cells Sensor Models |
Features | LED Display |
Operation Mode | Manual |
Display Size | 1.3 inch |
Power Source | Battery |
Battery Capacity | 1200 mAh |
View Complete details
Instrument Name | Breath Analyser |
Brand | Amrutha |
Parameters | Blood Alcohol Content |
User Input | Touch |
Type Of Breath Alcohol Analyzer | Fuel Cells Sensor Models |
Features | LCD Display |
Operation Mode | Manual |
Power Source | Battery |
Blowing Time | 4 to 5 seconds continuously |
Measuring Range | 0.00-2.0(1.00mg/L) |
SPECIFICATIONS
_ Build in DSP microprocessor technology, Sensor Highly selective semi-conductive oxide. CE approval by FIMKO
_ Warm up time : less than 20 seconds (typical)
_ Power source : 9V NI MH Rechargeable battery.
_ Size : 115x60x23mm
_ Measuring range : 0.00-2.0(1.00mg/L)
_ Accuracy : +/- 0.015%BCA at 0.05%BAC
_ Blowing time : 4 to 5 seconds continuously.
_ Calibration : Availed upon request (every 12 months).
_ Removable mouthpiece, easy to clean and replace.
_ Unique 4 digits LCD display
_ 5 Memories for last tested result
_ Illumination for use in dark (Auto shut off after 20 seconds)
Breath Tester used as a monitor, it can indicate when equivalent blood alcohol percentages are below or above the legal limits
DESCRIPTION:
The Alcohol Breath Tester is commonly used at home, bar, laboratory, Police, Military, and Airport or while you are on the road Device provided with extra mouthpieces for convenience. Units activated through a micro switch, after a brief internal self test; the test subject blows through the sensor and result are converted and read within few seconds.
View Complete details
Instrument Name | Breath Analyser |
Parameters | Blood Alcohol Content |
User Input | Touch |
Accuracy | +/- 0.0151/4A at 0.05 Degree Celsius |
Type Of Breath Alcohol Analyzer | Fuel Cells Sensor Models |
Operation Mode | Manual |
Types Of Breath Alcohol Analyzer | Semiconductor Sensor Models |
Measuring Range | 0.00-2.0(1.00mg/L) |
Size | 115 x 60 x 23 mm |
Power Source | Battery |
Battery Capacity | 1200 mAh |
Model No | AT500 |
SPECIFICATIONS
_ Build in DSP microprocessor technology, Sensor Highly selective semi-conductive oxide. CE approval by FIMKO
_ Warm up time : less than 20 seconds (typical)
_ Power source : 9V NI MH Rechargeable battery.
_ Size : 115x60x23mm
_ Measuring range : 0.00-2.0(1.00mg/L)
_ Accuracy : +/- 0.015%BCA at 0.05%BAC
_ Blowing time : 4 to 5 seconds continuously.
_ Calibration : Availed upon request (every 12 months).
_ Removable mouthpiece, easy to clean and replace.
_ Unique 4 digits LCD display
_ 5 Memories for last tested result
_ Illumination for use in dark (Auto shut off after 20 seconds)
Breath Tester used as a monitor, it can indicate when equivalent blood alcohol percentages are below or above the legal limits
DESCRIPTION:
The Alcohol Breath Tester is commonly used at home, bar, laboratory, Police, Military, and Airport or while you are on the road Device provided with extra mouthpieces for convenience. Units activated through a micro switch, after a brief internal self test; the test subject blows through the sensor and result are converted and read within few seconds.
View Complete details
Instrument Name | Breath Analyser |
Parameters | Blood Alcohol Content |
User Input | Keyboard |
Brand | Amrutha |
Features | LCD Display |
Operation Mode | Manual |
Storage Environment Temperature | -20 Degree Celsius to +75 Degree Celsius |
Operating Temperature | 5 to +45 Degree Celsius |
Memories | 200 Records |
Dimension | 103 x 55 x 15 mm |
Measurement Accuracy | +/-0.03 mg/L at alert point |
Features:
View Complete details
Instrument Name | Breath Analyser |
User Input | Touch |
Accuracy | +-10% F.S |
Brand | Amrutha |
Operation Mode | Manual |
Sensor Type | flat surfaced alcohol sensor |
Working Voltage | DC4.5V(3xAAA)Batteries |
Working Current | Less Than or equal 120mA |
Working Environment Temperature | -10 degree Celsius~50 degree Celsius |
Relative Humidity | Less Than or equal 95% No Dews |
Response Time | Less than or Equal 20s |
Dimension | 103 x 65 x 27mm (L x W x H) |
1.Sensor type: flat surfaced alcohol sensor
2.Working Voltage: DC4.5V(3×AAA)Batteries
3.Working Current: ≤120mA
4.Working Environment: Temperature -10°C~50°C
5.Relative Humidity ≤95% No Dews
6.Detection Range: 0.00~1.00mg/L
0.00~0.20%BAC; 0.00~2.00g/L; 0.00~2.00‰BAC
7.Alarming Level: 0.25mg/L (0.05%BAC, 0.50g/L; 0.50‰BAC)
8.Accuracy: ±10% F.S
9.Response Time: Resume Time: ≤20s
10.Display: 3 digits LCD display with light blue backup
11.Dimension: 103×65×27mm (L×W×H), ≤64 g Battery excluded
12.Battery expectancy time: ≥200Times
View Complete details
Minimum Order Quantity: 1 Piece
Warning Signal | Beep |
Brand | Amrutha |
Dimensions | 100 x 37 x 17mm |
Detect Range | 0.00~0.19 % BAC & 0.0~1.9g/L |
Body Material | ABS Plastic |
Power Source | Electric |
Model No | 6389A2 |
View Complete details
Usage/Application | Law Enforcement Agencies |
Brand | Amrutha |
Warning Signal | Beep |
Display | LCD Display |
Type of Mouthpiece | Replaceable |
Temperature Range | 20 to +70 Degree Celsius, (-20 Degree Celsius to +40 degree Celsius |
Display Range | 0~0.4% BAC or 0~4.0%oBAC or 0~2.0mg/l |
Storage Environment Temperature | -40 Degree Celsius to +85 Degree Celsius |
Model No | AT 333 |
Body Material | ABS Plastic |
Features:
View Complete details
Minimum Order Quantity: 1 Piece
Instrument Name | Breath Analyser |
User Input | Keyboard |
Brand | Amrutha |
Features | Handheld/Portable, LCD Display |
Display | LCD Display |
Operation Mode | Manual |
Analyzing Time | 3 s |
Clearing Time | 6 s |
Continuous Working Time | 8 Hours |
Temperature Range | 0 to 50 Degree Celsius |
Dimensions | 15 x 5 x 3 cm |
Frequency | 31.5 Hz |
Material | Plastic |
Weight | 150 gm |
Model No | KT-8000P |
Blowing Time | 3 Sec |
View Complete details
Application | Law Enforcement Agencies |
Brand | Amrutha |
Warning Signal | Beep |
Display | LED Display |
Analyzing time | 3 s |
Clearing time | 6 s |
Continuous Working Time | 6 hr |
Pre Heating Time | 5 sec |
Operating Temperature | -5 Degree Celsius - +50 Degree Celsius |
Condition Pressure | 600-1400 hPa |
Condition Humidity | 20-98% r.h |
Measurement Time | More than 1000 times testing |
Power Save Mode | Automatic switch off after 2.5 minutes without use |
Battery Capacity | 1300 mAh |
Battery Voltage | 7.4 V |
Dimension | 170 x 70 x 30 mm |
Weight | 125 gm |
Model No | A-20 |
Measurement Mode | Active Mode and Passive Mode | |
Sensor type | Fast Fuel Sensor | |
Display | 2.4 inch color TFT display | |
Mouth Pieces | Yes | |
Units | ºC, mg/L, mg/100ml BAC | |
Measurement Range | (0-550) mg/100ml BAC | |
Accuracy | Range (0-88) mg/100ml | ± 4.4 mg/100ml |
Range(88-220)mg/100ml | ± 5% absolute | |
Range > 220mg/100m | ± 10% absolute | |
Measurement Range | (0-2.5) mg/L BrAC | |
Accuracy | Range ( 0.00-0.40) mg/L | ± 0.020 mg/L |
Range ( 0.40-1.00) mg/L | ± 5% absolute | |
Range > 1.00 mg/L | Range > 1.00 mg/L | |
Memory | 20,000 |
View Complete details
Instrument Name | Breath Analyser |
User Input | Touch |
Brand | Amrutha |
Operation Mode | Manual |
Sensor Type | Flat Surfaced alcohol sensor |
Working Voltage | DC4.5V(3XAAA)Batteries |
Working Current | <120mA |
Working Environment: Temperature | -10 degree Celsius~50 degree Celsius |
Detection Range | 0.00~1.00mg/L,0.00~0.20%BAC; 0.00~2.00g/L; 0.00~2.00A DegreeBAC |
Alarming Level | 0.24mg/L (0.05%BAC, 0.50g/L; 0.5%BAC) |
Dimension | 103 x 65 x 27 mm |
1.Sensor type: flat surfaced alcohol sensor
2.Working Voltage: DC4.5V(3×AAA)Batteries
3.Working Current: ≤120mA
4.Working Environment: Temperature -10°C~50°C
5.Relative Humidity ≤95% No Dews
6.Detection Range: 0.00~1.00mg/L
0.00~0.20%BAC; 0.00~2.00g/L; 0.00~2.00‰BAC
7.Alarming Level: 0.25mg/L (0.05%BAC, 0.50g/L; 0.50‰BAC)
8.Accuracy: ±10% F.S
9.Response Time: Resume Time: ≤20s
10.Display: 3 digits LCD display with light blue backup
11.Dimension: 103×65×27mm (L×W×H), ≤64 g Battery excluded
12.Battery expectancy time: ≥200Times
View Complete details
Minimum Order Quantity: 1 Piece
Instrument Name | Breath Analyser |
Usage/Application | Laboratory |
User Input | Touch |
Brand | Amrutha |
Type Of Breath Alcohol Analyzer | Fuel Cells Sensor Models |
Display | LCD Display |
Operation Mode | Manual |
Calibration | Every 6 Months |
Dimensions | 128 x 59 x 26.5 mm (L x W x T) |
Weight | 142 gm |
Resolution | 0.0001 mg/L |
Operation Temperature Range | -10 Degree Celsius-45 Degree Celsius |
Storage Temperature Range | -20 Degree Celsius - 70 Degree Celsius |
Humidity | <80%RH |
Pressure | 86 kpa |
Blowing Time | 3 Sec |
Display Size | 1.8 inch |
Memory Capacity | Stores 4000 measured values with date and time |
Printer | Micro Thermal Printer |
Operation Voltage | DC 3.6V-8.4 V |
Batteries Capacity | 1000mAh |
Details | Technical Data | |
Principle of Measurement | Electrochemical Sensor, alcohol- specific | |
Measurement Range(BrAC) | 0.000mg/L???1.500 mg/L | |
Resolution | 0.0001 mg/L | |
Accuracy: | Ethanol Vapor Concentration / (mg/L) | Deviation |
Max. Measure error, | C<0.400 | ±0.020 mg/L |
in relation to ethanol standard | 0.400≤C<1.000 | ±5% |
C≥1.000 | ±20% | |
Repeatability of Indicating Value | Ethanol Vapor Concentration / ( mg/L) | Deviation |
C<0.400 | 0.007 mg/L | |
0.400≤C<1.000 | 1.75??? | |
C≥1.000 | 6??? | |
Optimum Storage Condition | Temperature???20???±5??????Humidity???<80%RH???Pressure???86 kpa???106 kpa | |
No vapor or electromagnetic disturbances in the environment are influencing the normal working conditions of the device | ||
Operation Voltage | State of charging | State of operation |
USB port, 5V | DC 3.6V???8.4 V |
View Complete details
Instrument Name | Breath Analyser |
Model Number/Name | KT-4000P |
User Input | Air Blow |
Brand | Amrutha |
Types Of Breath Alcohol Analyzer | Fuel-Cells Sensor Models |
Display | Digital |
Analyzing time | 3 s |
Frequency | 50 Hz |
Display Size | 2.8 inch LCD screen |
Power Source | Battery |
Battery Capacity | 1200 mAh |
View Complete details
Instrument Name | Breath Analyser |
Brand | Amrutha |
Parameters | Blood Alcohol Content |
User Input | Touch |
Type Of Breath Alcohol Analyzer | Fuel Cells Sensor Models |
Features | LCD Display |
Operation Mode | Manual |
Weight | 115 gm |
Resolution | 0.001mg/L |
Blowing Time | 3 Sec |
Power Source | Battery |
Battery Capacity | 1000 mAh |
Features:
View Complete details
Instrument Name | Breath Analyser |
Brand | Amrutha |
Parameters | Blood Alcohol Content |
User Input | Touch |
Type Of Breath Alcohol Analyzer | Fuel Cells Sensor Models |
Operation Mode | Manual |
Display Size | 2.2 inch LCD display |
Storage Environment Temperature | -20 Degree Celsius to +75 Degree Celsius |
Operating Temperature | 5 Degree Celsius to +45 Degree Celsius |
Memories | 200 Records |
Dimension | 103 x 55 x 16 mm |
Keyboard | 5 keys operation: ,“Up”, “Down”, “Left”, “Right”, “OK” |
Power Supply | Interchangeable rechargeable battery; |
Heat warm up:: | Chamber & Sensor warm up automatically |
Auto flow monitoring. | Flow detect automatically (Patented) |
Compact sampling system: | Low power consumption (Patented) |
Passive test: | Quick test within 1 sec. |
Measurement Accuracy: | +/–0.03 mg/L at alert point |
Drift: typically < 1.0 % of the measurement value/month | |
CERTIFICATED | GB/T 21254-2007; Ukraine Mark II |
Standard gift box packing: | Including White box; 2 pcs blow tubes , USB charger cable; |
Printer interface (OPTION) | By RS232 cable (Printer not included) |
Indicator | Instructing LED for indication |
View Complete details
Usage/Application | Law Enforcement Agencies |
Brand | AMRUTHA |
Warning Signal | Beep |
Measurement Range | 0~ 80mg/100ml BAC |
Accuracy | 0.001 |
Features | FUEL CELL |
Display | LED Display |
1. UK made Electrochemical/Fuel cell sensor with high reliability; 2. Quick and Precise Analysis; 3. Rapid and convenient, do not need mouthpieces; 4. With Traffic baton and flashlight illumination function 5. Large battery capacity, can testing for 8 hours.
View Complete details
Usage/Application | Workplace |
Brand | AMRUTHA |
Warning Signal | Beep |
Measurement Range | 0~ 80mg/100ml BAC |
Accuracy | 5% |
Features | FUEL CELL |
Display | LED Display |
Type Of Mouthpiece | Fixed |
Model Name/Number | Fuel-Cells Sensor Models |
Product Specification |
|
Product No: |
AT032 ~NEW~ |
1. product description: |
Quick alcohol screening test function with fuel cell sensor |
2. Power supply:: |
3*1.5V AAA Alkaline battery |
3. Display:: |
1.5” Color OLED |
4. Keyboard:: |
“OK”, “UP” & “DOWN” |
5. Sensor |
Replaceable fuel cell sensor module. |
6. unit setting:: |
mg/L mg/100mL BAC |
7. test mode: |
Quick active and passive test mode |
8. Operated environment:: |
-5 Degree C to +45 Degree C |
9. Storage environment:: |
-40 Degree C to +60 Degree C |
10. Display range:: |
0.00~2.0mg/l BAC or 0~4.0‰BAC or 0~0.4ºC |
11. Breath sampling:: |
about 0.5 seconds breath sample |
12. Memories:: |
50 test records with time stamp |
View Complete details